Add to Cart
400V/600V Low Voltage Electrical Switchgear Panel Drawer Low Voltage Switchgear
Products Description
1. GCK drawer switchgear is suitable for distribution system of power plant, high building and some lines, such as petroleum chemistry and industry, metallurgy, textile, etc. it is applicable for distribution, motor centralized control, reactive power compensation in power generation and power supply system of three phase AC 50/60Hz, rated voltage 380V (400V,600V), rated current 4000A and below, where require high automation and interfaces with computers.
2. The design of the GGD cabinet fully takes into account the heat dissipation during the operation of the cabinet. There are different numbers of heat dissipation slots at the upper and lower ends of the cabinet. When the electrical components in the cabinet are heated, the heat rises and is discharged through the upper slot, and the cold air is continuously replenished into the cabinet by the lower slot to make the sealed cabinet to form a natural air passage from the bottom to the end for heat dissipation.
3. GGD cabinet according to the requirements of modern industrial product design, using the golden ratio method to design the cabinet shape and the size of each part of the division, which are beautiful and generous, fresh. The hinge of the cabinet door is connected with the frame, which is convenient for installation and disassembly. A mountain-shaped rubber strip is embedded in the folded edge of the door. When the door is closed, the insert between the door and the frame has a certain compression stroke, which can preven the door from cracking the cabinet and also increases the degree of protection of the door. The instrument door with electrical components is connected to the frame by lots of soft copper coins. The mounting piece and the frame in the cabinet are connected by knurled screws, and the whole cabinet constitutes a complete grounding protection circuit.
4. The main circuit of the GGD cabinet is designed with 129 schemes and a total of 298 specifications (excluding the functional changes of the auxiliary circuits and the control schemes and specifications derived from the control voltage).
Rated isolation voltage | To 1000V |
Rated operational voltage | To 600V |
Rated frequency | 50 /60 Hz |
Rated impact withstand voltage | 8 kV |
Rated voltage of auxiliary circuit | AC380, 220V,DC 220V |
Over voltage degree | III |
Pollution degree | 3 |
Rated current | 4000A |
Horizontal busbar rated current | 4000A |
Vertival busbar rated current | 2000, 1000A |
Note: Due to continuous product improvement, the dimensions provided in this sample are for reference only. If necessary, our company can design and produce according to user requirements. Please contact the company in time.
1. Indoor altitude above sea level: Maximum installation altitude: 2000m
2. Ambient air temperature: -5℃~+40℃ and the average temperature should not
exceed +35℃ in 24h
3. Relative humidity should not exceed 50% at max temperature +40℃. Higher
relative humidity is allowed at lower temperature. Ex. 90% at +20℃. But in view of
the temperature change, it is possible that moderate dews will produce casually.
4. No fire, explosion danger, serious pollution, chemical corrosion and severe vibration
5. Installation gradient not exceed 5°
6. This product is suitable for the following temperature transportation storage: -25℃ ~+55℃ 24h, in a short period of time (no more than 24hours) not more than+70℃.
This series of products with high breaking capacity, good dynamic stability, advanced and reasonable structure, electrical program of practical, series, strong versatility, various schemes of unit combination, a cabinet contained many circuits, save the area , beautiful appearance, high level protection, safe and reliable, convenient maintenance etc.
It accords with the standards IEC439 NEMA ICS2-322 as well as the GB7251-87 “Low voltage complete switch device ” national standards and ZBK36001-89 "low voltage withdraw type complete switch device” professional standards"